Application:
The instrument is used for collection and long distance transfer of outdoor pH/ORP data, it can be used as PLC control in compositive small and medium sized water treatment system or used for collection of Oxidation –Reduction potential signal offerred by DCS system.
Features:
Four-wire transmitter; identify polar by itself
Isolated 4-20mA output, forward / oppsite direction could be transfferd at random
DC24V power supply
Standard IP65 seal organization
Instrument / Transmitter mode
Digital display on-site
Model: ORPT-5421 pHT-5431
Name: Oxidation-Reduction Potential transmitter pH Transmitter
Auxiliary sensor: ORP sensor pH sensor
Measure range: -1000 mV ~+1000mV 0~14
Resolution ratio: ±1mV 0.01
Accuracy: ≤±5mV ≤±0.1
Stability: ≤±2×10-3(FS)/24h
Compressure resis-tance of sensor: 0~0.6MPa
Output signal:
isolated, transferrable , reversable 4-20mA output, active and passive output can be selected
The maximum resistivity load: 500Ω Max(24V DC)
Working environment: temperature 5~50℃
Power supply: DC 24V±10%
Outline dimension: 130 mm×70 mm×50mm